Scif door requirements.
While each facility impacts the specific scif there are a number of standards every scif must follow.
A scif sensitive compartmented information facility is the u s.
3 3 3 3 all scif primary entrance doors must be equipped with an automatic door closer a gsa approved combination lock and an access control device with the following requirements.
Talk directly to one of our stc scif door experts.
If doors are equipped with hinge pins located on the exterior side of the door where it opens into an uncontrolled area outside the scif the hinges will be treated to prevent removal of the door e g.
The first scif door locks to have a chamfered bolt designed to provide smooth non binding entry into the strike plate.
Department of defense s term for a secure room.
It is a data center where sci sensitive compartmented information can be stored discussed and electronically processed.
Houston starr is only providing general guidelines for construction of your partition as it relates to stc door installation.
Krieger s 705 scif door and lock package meets scif sound groups 3 and 4 standards and comes with an installed kaba mas sargent and greenleaf or lockmasters locking device.
Accreditation is the formal approval that a space meets the prescribed physical technical and operational standards.
To be operational a scif or sapf must be accredited.
Ic scif comply with uniform ic physical and technical security requirements.
Scif doors must be solid wood core or a specially constructed door filled with sound attenuation material of stc 45 rating or higher.
Field stc acoustical requirements have become much more stringent and testing methods far more difficult to meet.
A scif or sapf is established when there is a clear operational requirement that is crucial to the command s mission.
The only single motion egress scif door locks currently available that fully meet the updated requirements of gsa ff l 2890bc regulations.
Door frame hinges closer locking device threshold door bottom and seal system.
Sound sealing door gaskets and door sets must also be rated at a minimum of stc45.
One of the most challenging aspects of scif build outs is the proper installation of the scif door.
Intelligence community standard ics 705 1 and the ic tech spec for icd ics 705 provide the physi cal and technical security standards for all sclf including existing and.
In the case of retrofitting an existing room to scif specifications even wood fillers must meet sound suppression requirements.