Drip edge metal valley flashing dormer chimney and kickout flashing are types of roof flashing that shed water away from the connections between roofs walls chimneys and other building assemblies.
Sidewall flashing at roof lines.
Epdm flashing tape with a butyl adhesive backing will help.
You can see that i m letting it run past the end of the roof and past the ridge line.
Flashing is installed to surround roof features such as vents chimneys and skylights.
Except where walls are brick the vertical part of the sidewall flashing should extend up behind the exterior wall covering just like with headwalls.
Roof flashing is a thin material usually galvanized steel that professional roofers use to direct water away from critical areas of the roof wherever the roof plane meets a vertical surface like a wall or a dormer.
This article describes mistakes at roof dormer sidewall flashing and roof dormer sidewall coverings that invite leaks rot and insect damage on buildings.
The metal flashing is formed with a hook edge and cleated on 12 centers.
A sidewall is a junction between a wall and a sloped portion of a roof.
We re going to install this step flashing here against the sidewall and the first thing we re going to do is let it run.
Even if the roof has been properly flashed against the sidewall this one hasn t water can still run down the side of the house and behind the siding causing rot.
Here s how to install it correctly.
The flashing should be partially exposed along the wall.
The flashing extends up the wall at least 4.
Another term for this is a step flashing.
Pieces of step flashing are bent at an angle relative to the roof pitch and installed along the full length of the sidewall where it joins the roof deck.
The solution to rotting sidewalls is a small piece of bent metal called a kickout flashing at roofing suppliers which simply directs all that water away from the wall.
Installing step flashing to prevent roof leaks step flashing spans the joint between roof shingles and an adjacent side wall.
The horizontal part of the flashing will vary depending on the type of roof covering material.
It s kind of like a step so water hits it comes off and moves off the roof.
The flashing extends onto the roof a minimum of 2 inches 4 inches is preferable in more severe climate areas.
Flashing joints are lapped 6 in the direction of water flow.